Panel Maker Division

PT. Besa Sekar Guna manufactures panels to a comprehensive panel system including: Inverter Panels, Panel Automation, Capacitor Banks, Soft Starters, Main Distribution Panels (MDP), Sub Distribution Panels (SDP), Star-Delta Panels, Direct On Line Panels (DOL), AMF and ATS Panels.

Application:

  • Government Project (PDAM)
  • All types of industries
  • Commercial estate & real estate
  • Hospital, hotel & apartment
Why us?

We provider consultation service from design to system directly to experienced engineer.

High customization level to create a dedicated panel function according to your need and budget.

We use the best material at the price level to make sure you will get the best result.

Main Distribution Panel

The MDP panel can be known as the main voltage switch or the center for power distribution. The MDP panel also serves to accommodate loads or as a main circuit breaker and provides protection, which can also be called a Circuit Breaker. The MDP panel is also equipped with indicators to provide information on the status of the circuit currently running. Examples of MDP Panel Usage:

  • Installation of the panel after the PLN substation before entering the factory machinery
  • Installation of the panel after the Genset before entering the factory machinery
  • Installation of the panel after the Solar System panel before entering the house or factory electrical installation
Sub Distribution Panel

The SDP panel can also serve as a control center that draws power from the MDP panel to distribute or supply power to smaller circuits. Each circuit in the SDP panel is equipped with an indicator to show the status of the circuit, whether there is power flow or not. SDP panels are often placed near the panels that will be powered more locally, providing flexibility and adapting to power needs in specific areas. Examples of SDP Panel Usage:

  • Installation of the panel after the MDP panel before entering the factory machinery
  • Installation of the SDP panel on each machine
  • Installation of the SDP panel as a local junction box in an electrical system
Soft Starter Panel

This Soft Starter panel has a function that is quite similar to an Inverter Panel, which is to control the acceleration or deceleration of a motor in a smoother manner during motor starting mode. This panel is commonly used to help reduce current surges when starting a motor by controlling the voltage supplied to the motor gradually. Some can be controlled through a user-friendly interface, allowing for the adjustment of parameters such as acceleration time, deceleration time, and voltage level. Examples of Soft Starter Panel Usage:

  • Installation of a Soft Starter panel to replace a DOL or Star Delta panel
  • Installation of a Soft Starter panel for cranes to provide smoother initial starting
  • Installation of a Soft Starter panel for machines to reduce initial power consumption and provide smoother operation
DOL (Direct On Line) Panel

This circuit is designed and commonly used as a control system for electric motors. This panel is also suitable for motors with low to medium power. The main switch on the DOL is also used as a motor controller to turn the power on or off to the electric motor. Examples of DOL Panel Usage:

  • Installation of a DOL panel for low-power pump installations (below 7.5 kW)
  • Installation of a DOL panel for simple machine installations
  • Installation of a DOL panel for Genset installations
Star Delta Panel

A Star Delta panel is used for electric motors to reduce excessive starting current. The motor operation starts in a star connection to minimize the high starting current when the motor is turned on. Once the motor has operated according to its operational requirements, the panel will change the configuration to a delta connection to increase the motor’s operating efficiency. This panel is commonly used in industries that require motor starting with a controlled starting current. Examples of Star Delta Panel Usage:

  • Installation of a Star Delta panel for pump installations with high power above 7.5 kW
  • Installation of a Star Delta panel for crane or machine installations
  • Installation of a Star Delta panel for hydrant or fire pumps
Inverter Panel

An inverter is a device used to control the speed of a motor by changing the frequency value. The basic operating principle of an inverter is by converting AC voltage into DC voltage and then converting it back into AC voltage with a different or adjustable frequency, so that there is a speed that is suitable for the application. The use of inverter panels is very helpful in saving energy and improving power efficiency. Inverters also have special pump features such as flow calculation, dry run pump, and self-cleaning, which function to ensure that the pump can operate at maximum capacity. Examples of Inverter Panel Usage:

  • Installation of an inverter panel to replace a DOL or Star Delta panel
  • Installation of an inverter panel on a crane or pump motor
  • Installation of an inverter panel on a machine that runs continuously without stopping
Capacitor Bank Panel

A Capacitor Bank panel is an electrical device commonly used in office buildings or industries to optimize the use of electrical power. With it, it can improve the efficiency of electricity usage and reduce power loss factors in the system. It usually consists of several Capacitor Banks connected and can also be connected or disconnected according to the use of electrical power. Examples of Capacitor Bank Usage:

  • Installation of a Capacitor Bank panel at the initial factory installation after the MDP panel
  • Installation of a Capacitor Bank panel on each machine or motor with large power
Jockey Pump Panel

It functions to stabilize the pressure in the hydrant pipe and can also be used to extinguish fires if the fire is still small. Examples of Jockey Pump Panel Usage:

  • Installation of a Jockey Pump panel in a fire hydrant pump system
  • Installation of a Jockey Pump panel when the pump acts as a backup in a system
Electric Hydrant Pump Panel

The electric pump system is designed to start automatically when the water pressure drops significantly, indicating a fire, and the jockey pump is unable to maintain the required pressure.

Example use of electric hydrant pump:

  • Installation of an Electric Hydrant Pump panel in a fire hydrant pump system.
DC Hydrant Pump Panel

For the DC hydrant system itself, it functions when the PLN electricity goes out, the hydrant system remains on because it uses the engine battery.
Example of Using the DC Hydrant Pump Panel:

  • Installation of the DC Hydrant Pump panel on the fire hydrant pump system
ATS Panel

ATS Panel is a panel that functions to transfer voltage from PLN to be distributed to the generator and can automatically turn on the generator when PLN is out or one of the currents is cut off. The ATS panel also automatically detects when the main power source (PLN) has no voltage or is experiencing interference, then at that time the ATS automatically switches to the backup power source (generator) to ensure that the power supply continues. ATS panels are also commonly used in Buildings, Hospitals, Hotels, Apartments and Industries that require continuous voltage.

Example of Using ATS Panel:

  • Installation of ATS panel for switching between PLN and Generator